Vehicle interior

7-8 PSV heating and ventillation

Reasons for rejection

Mandatory equipment

1. A PSV does not have ventilation that is provided by at least one of the following:

a) opening windows or roof hatches,

b) forced ventilation.

2. The driver does not have at least one independently adjustable means of ventilation.

Condition and performance

3. A window or roof hatch used for ventilation cannot be easily opened.

4. A forced ventilation system:

a) does not operate, or

b) has insufficient air flow.

5. An interior heating system is installed in a way that does not minimise the risk of occupants being burned.

6. The operation of an interior heating, ventilation or air-conditioning system introduces harmful gases into the vehicle.

Summary of legislation

Applicable legislation
Mandatory equipment

1. A PSV must have ventilation that is provided by:

a) opening windows or roof hatches, or

b) forced ventilation.

2. The driver must have at least one independently adjustable means of ventilation.

Condition and performance

3. The ventilation system must provide adequate ventilation throughout the length of the passenger compartment.

4. An interior heating system must be installed in a way that will minimise the risk of occupants being burned.

5. An interior heating or air-conditioning system must be designed and constructed so that no harmful fumes associated with its operation can be introduced into the vehicle.

6. Ventilation air intakes must be in a position which minimises the possibility of introducing exhaust gases or other harmful fumes into the passenger compartment.

Back to top